SFS-200 HFC-227ea (FM-200) Gas Fire Suppression System

Product Description

S-TEC VINA's SFS-200 system uses HFC-227ea (FM-200) extinguishing agent – a clean agent that is non-conductive, non-corrosive and leaves no residue after discharge. Extinguishing fires within seconds, the SFS-200 is ideal for areas housing electronic equipment, data centers, control rooms and document archives.

Extinguishing principle

The SFS-200 system works by absorbing heat and interrupting the combustion chain reaction. When activated, HFC-227ea is discharged as a clean vapor that spreads quickly throughout the protected space. The agent absorbs heat from the fire zone while interrupting the chemical reaction that sustains the flame, extinguishing the fire within seconds. The process does not significantly reduce oxygen levels, so it is safe for people at the design concentration, causes no damage to electronic equipment and leaves no residue after discharge. Thanks to this mechanism, SFS-200 is the optimal solution for areas that demand fast, clean and safe fire suppression, such as data centers, server rooms, electrical panels, control rooms and archives.

Key advantages of HFC-227ea (FM-200)

Fast fire suppression

Extinguishes fire in just 5–10 seconds by absorbing heat and breaking the combustion chain reaction, stopping fire spread at the earliest stage.

Safe for electronic equipment and assets

A clean agent that is non-conductive, non-corrosive and residue-free, providing optimal asset protection in the event of a fire.

Safe for people

Non-asphyxiating and non-toxic when discharged at the correct design concentration; certified by international bodies as safe for use in occupied spaces.

Suitable for multiple fire classes

Effective on solid, liquid, gas and electrical fires – a flexible, comprehensive fire suppression solution for a wide range of applications.

Lower operating and maintenance costs

Reliable operation with minimal servicing and no frequent replacement of consumables – reducing total cost of ownership over the long term.

Simple maintenance

Minimal complex maintenance required, saving long-term operating costs.

Applications

Gas fire suppression applications by project type

Technical specifications

Depending on the project, our engineers will recommend the most suitable extinguishing agent to optimize cost and minimize damage to the facility.

Contact S-TEC VINA for advice on the SFS-200 HFC-227ea (FM-200) gas fire suppression system

Product Single Form
en_USEN