SMS-227
Automatic Fire Suppression Cylinder System

Description

The SMS-227/5112 system was researched and developed by S-TEC VINA specifically for electrical rooms, electrical service tunnels and small areas where water, powder or foam systems are unsuitable – and for any area requiring automatic fire suppression, particularly clean agent systems. The SMS-227/5112 uses one of two extinguishing agents: HFC-227ea (FM-200) or FK-5-1-12 (Novec 1230). The agent is stored in the cylinder as a liquefied gas, pressurized with nitrogen to 25 bar. It is a clean, colorless and odorless agent, safe for people at the design concentration, non-conductive and residue-free after discharge. HFC-227ea (FM-200) / FK-5-1-12 (Novec 1230) disperses naturally after discharge and causes no damage to electrical or electronic equipment.

Working principle

When the temperature in the protected area reaches 68°C, the glass bulb heat detector bursts automatically (bulbs with different temperature ratings are available to suit each project), triggering discharge of HFC-227ea or FK-5-1-12. Within 10 seconds the agent is discharged and spreads evenly through the space. On contact with areas above 101°C, the agent absorbs heat and locally reduces oxygen concentration while interrupting the combustion chain reaction, extinguishing the fire quickly and completely without damaging equipment.

What sets the SMS automatic fire suppression cylinder apart

Fast, highly effective fire suppression

Discharge time within 10 seconds, extinguishing the fire before it spreads and providing maximum protection for assets and equipment.

Safe for equipment and people

HFC-227ea / FK-5-1-12 is non-conductive, non-corrosive, residue-free and safe at the design concentration, suitable for occupied areas.

Optimized cost and operation

Optimizes initial investment and total cost of ownership; cylinders can be refilled multiple times after discharge, significantly reducing operating and maintenance costs.

Ideal solution for small spaces

Designed for electrical rooms, cable tunnels, control centers and server rooms – where water, foam or powder cannot be used. Saves space and investment cost.

No damage, no residue after discharge

After discharge the agent disperses completely, causing no damage to electronic equipment and requiring no post-fire cleanup, so operations can resume quickly.

Environmentally friendly

Zero ODP and low GWP, with no ozone depletion – compliant with international environmental standards.

Applications

Gas fire suppression applications by project type

Technical specifications

Depending on the project, our engineers will recommend the most suitable extinguishing agent to optimize cost and minimize damage to the facility.

Contact S-TEC VINA for advice on the SMS-227 automatic fire suppression cylinder system